Transformers, Power Transformers, Toroids, Current Transformer

D.C. Linear Regulated Power Supply

Model 6218

D.C. Linear Regulated Power Supply available in single or dual output configurations and in fixed voltages from 5 volts to 48 volts. The regulators are temperature limited and time dependant current limited. The power supply incorporates a toriodal transformer which gives the unit a low weight and small size. Other advantages are low external field and elimination of transformer hum.


Specifications
Input Volts: 240 Volts 50/60 Hz, 110 Volts 50/60 Hz (available)
Load Regulation: Better than 0.5% no load to full load
Line Regulation: Better than 0.5% for 10% change in input volts
Total Noise: Less than 20mV R.M.S.
Protection: None. Input fuses should be rated 5 to 10 times full load input current
Current Limit: 2 A approx. (7A for 2A models) Output is short circuit protected for models up to 24 volts
Ambient Range: 0° - 55° Celsius
Dimensions: See below

Model Output
Volts D.C.
Output
Amps D.C.
Typical full load
input current*
Weight
kg
6218-X0
6218-X00
6218-X1
6218-X11
6218-X22
6218-X33
6218-X4
6218-X44
6218-X7
5
±5
12
±12
±15
±18
24
±24
48
2.0
1.2
1.2
1.2
1.2
1.2
1.2
0.6
0.5
0.05
0.10
0.10
0.17
0.18
0.19
0.18
0.18
0.25
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7

X = 0 for 110 Volts 50 Hz, X = 2 for 240 Volts 50 Hz, * 240V Input
 

Mains Input Variation: The power supply can be used at full current down to an input voltage of 210 Volts, however at low input voltages (below 240 volts) the output ripple will increase if the output current exceeds nominal output X [mains input voltage-190]/50. The Model 6218-20 power supply will give full output performance for voltages from 210 to 245. All power supplies can be used up to 255 Volts input, however above 245 Volts the maximum ambient temperature must be reduced by [mains input voltage-245] x 1degree celcius per volt.

Non-standard Voltages: These power supplies are available in non-standard input and output voltages.

Mounting: For maximum power out mount with the longest dimension vertical. Do not obstruct airflow.